Delta AIOC279K125L is an LFP battery energy storage system for commercial and industrial use with 279.6 kWh nominal energy. It supports 2 and 6 hour configurations and comes as an AC block with liquid or forced air cooling.
Use Cases
Delta AIOC279K125L has nominal energy in the commercial and industrial size class. It connects at 480 V, a low-voltage AC connection. It is certified to low-voltage grid connection rules under UL1741, IEEE1547, and UL1741SB. These specifications indicate use behind the meter.
Capabilities
Delta AIOC279K125L's AC block includes the inverter. That points to renewable colocation, storing output from a wind or solar plant on the same site. Its shortest listed configuration is 2 h, and the specifications suggest peak shaving, reducing the peak load at the connection point. Its longest listed configuration is 6 h. That configuration makes Delta AIOC279K125L a candidate for capacity value, counting as firm supply toward a network's peak needs.
Nominal energy
0.28 MWh
Rated AC power
0.13 MW
Duration
2–6 flexible
C / P rate
0.5 P
What does this system typically cost?
BESSBASE.com user price estimates for AIOC279K125L by Delta and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for AIOC279K125L by Delta and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
Site Space Required
Shared: one 3 m aisle serves both neighbours. Dedicated: each unit keeps its own 3 m, so gaps double to 6 m.
Single unit — matches the stored area_sqm convention.
More Delta Systems
3| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| Delta | M Series DC Block · 10 ft container | 7.78 MWh | — | — flex | LFP | |||
| Delta | AIOC279K125L AC Block · cabinet | 0.28 MWh | 0.13 MW AC | 2–6 h 0.5C · flex | LFP | |||
| Delta | AIOA279K125L AC Block · cabinet | 0.28 MWh | 0.13 MW AC | 2–6 h 0.5C · flex | LFP |
About the Vendor
Founded in 1971 and based in Taipei, Taiwan, Delta Electronics started in power and thermal management and later expanded into BESS for utility-scale use. It operates 165 sales offices, 55 manufacturing sites, and 73 R&D centers worldwide, and its ESS portfolio includes power conversion systems, battery systems, controls, EMS, financial optimization, and O&M, with a safety record dating to 2018.
How to Read the Product Page
This profile of AIOC279K125L by Delta is assembled exclusively from public data to support early-stage screening and requires additional due diligence.
Always confirm these terms and technical specifications directly with the vendor and project stakeholders. Reflect all agreed-upon details in the legal agreements before making any investment decisions.