For commercial and industrial use, iwell ALL-IN-ONE LIQUID COOLED is an LFP battery energy storage system supplied as an AC block, with 233 kWh nominal energy. Liquid cooling supports 89.7% AC round-trip efficiency. The system weighs 2.6 tonnes (5,732 lb).
Use Cases
iwell ALL-IN-ONE LIQUID COOLED falls within the commercial and industrial class by energy capacity and connects at 400 V, a low-voltage AC connection. These specifications indicate use behind the meter.
Capabilities
iwell ALL-IN-ONE LIQUID COOLED holds about 2.22 h of storage at full power, calculated from 233 kWh and 105 kW, which points to capacity value, being counted on as supply when the network is tight. Its AC block includes the inverter, and that configuration suggests renewable colocation, operating alongside a wind or solar plant on one site.
Nominal energy
0.23 MWh
Rated AC power
0.11 MW
Round-trip efficiency (AC)
89.7 % AC
What does this system typically cost?
BESSBASE.com user price estimates for ALL-IN-ONE LIQUID COOLED by iwell and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for ALL-IN-ONE LIQUID COOLED by iwell and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
Site Space Required
Shared: one 3 m aisle serves both neighbours. Dedicated: each unit keeps its own 3 m, so gaps double to 6 m.
Single unit — matches the stored area_sqm convention.
More iwell Systems
2| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| iwell | CONTAINERIZED LIQUID COOLED DC Block | 4.07 MWh | 7.5 MW AC | — 0.5–0.3C · flex | LFP | |||
| iwell | ALL-IN-ONE LIQUID COOLED AC Block · cabinet | 0.23 MWh | 0.11 MW AC | — | LFP |
About the Vendor
Founded in 2016, iwell is based in Utrecht, the Netherlands. It develops modular BESS and an in-house EMS for commercial and industrial customers across Europe, runs systems at more than 350 sites in four countries, uses a decade of operating data, and raised €27 million to expand into new markets.
How to Read the Product Page
This profile of ALL-IN-ONE LIQUID COOLED by iwell is assembled exclusively from public data to support early-stage screening and requires additional due diligence.
Always confirm these terms and technical specifications directly with the vendor and project stakeholders. Reflect all agreed-upon details in the legal agreements before making any investment decisions.