e-STORAGE CSI-FlexBank-S-8360-2h is an LFP battery energy storage system supplied as a DC block for utility-scale use. It provides 8.36 MWh nominal energy at about a 2-hour duration. The system uses liquid cooling, with 4.18 MW rated DC power and 93% DC round-trip efficiency.
Use Cases
e-STORAGE CSI-FlexBank-S-8360-2h has an energy capacity within the utility-scale range. That specification points to use in front of the meter on the utility's side of the connection.
Capabilities
e-STORAGE CSI-FlexBank-S-8360-2h lists its shortest configuration as 2 h; that configuration indicates grid services, support for the operation of the electricity network, and capacity value, standing in as firm capacity when demand peaks. Its DC block connects through a separate inverter, making it a candidate for renewable colocation, sitting next to a wind or solar plant and sharing its grid connection. That 2 h configuration points to peak shaving, cutting the power drawn from the grid at peak times.
Nominal energy
8.36MWh
Rated DC power
4.18MW
Duration
2hour
C / P rate
0.5P
Round-trip efficiency (AC)
93 %DC
What does this system typically cost?
BESSBASE.com user price estimates for CSI-FlexBank-S-8360-2h by e-STORAGE and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for CSI-FlexBank-S-8360-2h by e-STORAGE and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
Site Space Required
Shared: one 3 m aisle serves both neighbours. Dedicated: each unit keeps its own 3 m, so gaps double to 6 m.
Single unit — matches the stored area_sqm convention.
More e-STORAGE Systems
9| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| e-STORAGE | CSI-FlexBank-S-8360-2hDC Block · cabinet | 8.36MWh | 4.18MWDC | 2h0.5C | LFP314 Ah · Prismatic | |||
| e-STORAGE | CSI-FlexBank-S-8360-4hDC Block · cabinet | 8.36MWh | 2.09MWDC | 4h0.25C | LFP314 Ah · Prismatic | |||
| e-STORAGE | CSI-SolBank-S-PL-5016-2h-EUDC Block · 20 ft container | 5.02MWh | 2.4MWDC | 2h0.5C | LFP | |||
| e-STORAGE | CSI-SolBank-S-PL-5016-4h-EUDC Block · 20 ft container | 5.02MWh | 1.2MWDC | 4h0.25C | LFP | |||
| e-STORAGE | CSI-SolBank-S-5016-4h-EUDC Block · 20 ft container | 5.02MWh | 1.2MWDC | 4h0.25C | LFP314 Ah · Prismatic | |||
| e-STORAGE | CSI-SolBank-S-5016-2h-EUDC Block · 20 ft container | 5.02MWh | 2.35MWDC | 2h0.5C | LFP314 Ah · Prismatic | |||
| e-STORAGE | PowerBlock ESPB-2H | ESPB-4HAC Block | 4.8MWh | — | 1.5–4hflex | LFP | |||
| e-STORAGE | CSI-FlexBank-C-1672-4hDC Block · cabinet | 1.67MWh | 0.42MWDC | 4h0.25C | LFP314 Ah · Prismatic | |||
| e-STORAGE | CSI-FlexBank-C-1672-2hDC Block · cabinet | 1.67MWh | 0.84MWDC | 2h0.5C | LFP314 Ah · Prismatic |
About the Vendor
e-STORAGE is Canadian Solar’s battery energy storage business in Guelph and Kitchener, Ontario. Founded in 2001, Canadian Solar has shipped more than 20 GWh of battery energy storage systems to global markets, and its automated plants provide 15 GWh of annual BESS capacity and 3 GWh of battery cell capacity, along with system integration and EPC services for utility-scale projects.
How to Read the Product Page
This profile of CSI-FlexBank-S-8360-2h by e-STORAGE is assembled exclusively from public data to support early-stage screening and requires additional due diligence.
Always confirm these terms and technical specifications directly with the vendor and project stakeholders. Reflect all agreed-upon details in the legal agreements before making any investment decisions.