EVE Energy Mr. Giant 3.0 is an LFP battery energy storage system with 6.9 MWh nominal energy and a DC block. It uses 702 Ah prismatic cells.
Use Cases
The specifications of EVE Energy Mr. Giant 3.0 suggest use in front of the meter, connected to the utility network itself. Its nominal energy places it in the utility-scale size class.
Capabilities
The specifications suggest EVE Energy Mr. Giant 3.0 a candidate for renewable colocation, operating alongside a wind or solar plant on one site. Its DC block connects through a separate inverter.
Nominal energy
6.9MWh
What does this system typically cost?
BESSBASE.com user price estimates for Mr. Giant 3.0 by EVE Energy and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for Mr. Giant 3.0 by EVE Energy and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
More EVE Energy Systems
4| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| EVE Energy | Fortron SeriesDC Block · cabinet | — | — | 0.08–0.17h6–10C · flex | — | |||
| EVE Energy | Mr. Giant 3.0DC Block · cabinet | 6.9MWh | — | — | LFP702 Ah · Prismatic Next-Gen 500+ Ah | |||
| EVE Energy | EVE S556H201DC Block · 20 ft container | 5.02MWh | — | —0.5C | — | |||
| EVE Energy | T23IH201DC Block · cabinet | 0.26MWh | — | —0.5C | — |
About the Vendor
Founded in 2001 and based in Huizhou, Guangdong, EVE Energy makes consumer, power, and energy-storage batteries. It listed on Shenzhen ChiNext in 2009, had delivered 70 GWh of energy-storage batteries worldwide by mid-2024, and reported 71.05 GWh of energy-storage battery shipments in 2025.
How to Read the Product Page
This profile of Mr. Giant 3.0 by EVE Energy is assembled exclusively from public data to support early-stage screening and requires additional due diligence.
Always confirm these terms and technical specifications directly with the vendor and project stakeholders. Reflect all agreed-upon details in the legal agreements before making any investment decisions.