Solition Mega Three (Liquid cooled)
Grid-Scale AC Block 20 ft containerUpdated Sep 21, 2026
3.34 MWh nominal energy, Exide Technologies Solition Mega Three (Liquid cooled) is a containerized LFP battery energy storage system for utility-scale use. It is supplied as an AC block with about a 2-hour duration. The system has 94% AC round-trip efficiency and weighs 33 tonnes (72,752 lb).
Use Cases
Exide Technologies Solition Mega Three (Liquid cooled) has nominal energy in the utility-scale size class. It is certified to medium- or high-voltage grid connection rules (VDE4110), and these specifications indicate use in front of the meter.
Capabilities
Its shortest listed configuration is 2 h. That points to capacity value, standing in as firm capacity when demand peaks. The specifications suggest renewable colocation, sitting next to a wind or solar plant and sharing its grid connection, since Exide Technologies Solition Mega Three (Liquid cooled) includes the inverter in its AC block. That 2 h configuration makes it a candidate for peak shaving, cutting the power drawn from the grid at peak times, and indicates grid services, work that helps keep the electricity network running.
Nominal energy
3.34 MWh
Rated AC power
1.73 MW
Duration
2 hour
C / P rate
0.5 C
Round-trip efficiency (AC)
94 % AC
What does this system typically cost?
BESSBASE.com user price estimates for Solition Mega Three (Liquid cooled) by Exide Technologies and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for Solition Mega Three (Liquid cooled) by Exide Technologies and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
Site Space Required
Shared: one 3 m aisle serves both neighbours. Dedicated: each unit keeps its own 3 m, so gaps double to 6 m.
Single unit — matches the stored area_sqm convention.
More Exide Technologies Systems
4| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| Exide Technologies | Solition Mega Five (Liquid cooled) AC Block · 20 ft container | 5.02 MWh | 2.5 MW AC | 2 h 0.5C | LFP | |||
| Exide Technologies | Solition Mega Three (Liquid cooled) AC Block · 20 ft container | 3.34 MWh | 1.73 MW AC | 2 h 0.5C | LFP | |||
| Exide Technologies | Solition Mega One (Air cooled) AC Block · 20 ft container | 1.1 MWh | 1 MW AC | — 1–0.5C | LFP | |||
| Exide Technologies | Solition Mega Zero Five (Air cooled) AC Block · 10 ft container | 0.55 MWh | 0.5 MW AC | — 1–0.5C | LFP |
About the Vendor
Exide Technologies began as the Electric Storage Battery Company, which W.W. Gibbs founded in 1888. It now offers battery and energy storage systems through a BESS platform based on lithium-ion technology, including a 5 MWh liquid-cooled LFP system for grid-scale energy storage.
How to Read the Product Page
This profile of Solition Mega Three (Liquid cooled) by Exide Technologies is assembled exclusively from public data to support early-stage screening and requires additional due diligence.
Always confirm these terms and technical specifications directly with the vendor and project stakeholders. Reflect all agreed-upon details in the legal agreements before making any investment decisions.