For commercial and industrial use, E-HUB Cabinet 261k is an LFP battery energy storage system with 261 kWh nominal energy, supplied as an AC block. Liquid cooling supports 89% AC round-trip efficiency, and the system uses 314 Ah prismatic cells. It weighs 2.67 tonnes (5,886 lb) and operates within a 702 to 936 V DC window.
Use Cases
The specifications of E-HUB Cabinet 261k together point to use behind the meter. It falls in the commercial and industrial size class. It connects at 400 V, a low-voltage AC connection.
Capabilities
A 0.5P rating makes E-HUB Cabinet 261k a candidate for peak shaving, reducing the maximum power a site draws.
Nominal energy
0.26 MWh
Rated AC power
0.13 MW
C / P rate
0.5 P
Round-trip efficiency (AC)
89 % AC
What does this system typically cost?
BESSBASE.com user price estimates for Cabinet 261k by E-HUB and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for Cabinet 261k by E-HUB and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
Site Space Required
Shared: one 3 m aisle serves both neighbours. Dedicated: each unit keeps its own 3 m, so gaps double to 6 m.
Single unit — matches the stored area_sqm convention.
More E-HUB Systems
5| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| E-HUB | Container 5.0M AC Block · 20 ft container | 5.02 MWh | 2.5 MW AC | 2 h 0.5C | LFP 314 Ah · Prismatic | |||
| E-HUB | Container 4.2M AC Block · 20 ft container | 4.18 MWh | 2 MW AC | 2 h 0.5C | LFP 314 Ah · Prismatic | |||
| E-HUB | Container 2.5M AC Block · 20 ft container | 2.51 MWh | 1.25 MW AC | — 0.5C | LFP 314 Ah · Prismatic | |||
| E-HUB | Cabinet 418k AC Block · cabinet | 0.42 MWh | 0.22 MW AC | — 0.5C | LFP 314 Ah · Prismatic | |||
| E-HUB | Cabinet 261k AC Block · cabinet | 0.26 MWh | 0.13 MW AC | — 0.5C | LFP 314 Ah · Prismatic |