8.2 MWh nominal energy defines TeraStor Energy P8000 as a containerized LFP battery energy storage system, supplied as a DC block. Liquid cooling supports 3.6 MW rated DC power. Its DC voltage window spans 1164 to 1500 V.
Use Cases
The specifications of TeraStor Energy P8000 suggest use in front of the meter, connected to the utility network itself. Its nominal energy places it in the utility-scale size class.
Capabilities
TeraStor Energy P8000 specifications suggest capacity value, being counted on as supply when the network is tight. It holds about 2.28 h of storage at full power, calculated from 8.2 MWh and 3.6 MW. Its DC block connects through a separate inverter, which points to renewable colocation, storing output from a wind or solar plant on the same site.
Nominal energy
8.2 MWh
Rated DC power
3.6 MW
What does this system typically cost?
BESSBASE.com user price estimates for P8000 by TeraStor Energy and similar storage systems. The ranges are LDP (Landed Duty Paid) prices per kWh that cover all expenses of delivering the goods to the buyer's premises, including production, shipping, sales margins, and import duties.
Sign up to see and submit price estimates.
BESSBASE.com users can privately compare and submit prices for P8000 by TeraStor Energy and similar systems across 20+ international markets.
Energy & Power
Architecture
DC Side
AC Side
Physical & Footprint
Battery Cells
Lifespan
Protection
Full Specification Sheet
MembersThe rest of this spec sheet is for members
3 more specification blocks on this product. Create a free account to see every field on every product.
You stay on this page — it fills in as soon as you are signed in.
Plant Round-Trip Efficiency
The calculator estimates the full "plant" round-trip efficiency (RTE) at the point of interconnection. Some values are pre-blocked depending on information on a particular ESS. The rows that are marked "each way" are one-way efficiencies; they are applied on charge and again on discharge. We then square them. To enter a bundled PCS efficiency value, use its rated-power value, not peak. If the PCS skid already includes the LV/MV transformer, set Transformer LV/MV to 100 % so those losses are not counted twice.
Site Space Required
Shared: one 3 m aisle serves both neighbours. Dedicated: each unit keeps its own 3 m, so gaps double to 6 m.
Single unit — matches the stored area_sqm convention.
More TeraStor Energy Systems
5| Compare | Logo | Vendor | System | Energy | Power | Duration | Battery Cell | Open |
|---|---|---|---|---|---|---|---|---|
| TeraStor Energy | P8000 DC Block | 8.2 MWh | 3.6 MW DC | — | LFP | |||
| TeraStor Energy | S4000 DC Block | 4.07 MWh | 2 MW DC | — | LFP | |||
| TeraStor Energy | S1000 AC Block | 1.04 MWh | 0.5 MW AC | — | LFP | |||
| TeraStor Energy | S800 AC Block | 0.78 MWh | 0.38 MW AC | — | LFP | |||
| TeraStor Energy | S300 AC Block · cabinet | 0.26 MWh | 0.13 MW AC | — | LFP |
About the Vendor
TeraStor Energy became an independent company in 2023 and is based in Marlborough, Massachusetts. Its team has deployed grid-scale battery systems since 2007 across three continents and five system generations, and it designs and builds BESS units up to 8.2 MWh for utility grids, AI data centers, and mission-critical infrastructure.
How to Read the Product Page
This profile of P8000 by TeraStor Energy is assembled exclusively from public data to support early-stage screening and requires additional due diligence.
Always confirm these terms and technical specifications directly with the vendor and project stakeholders. Reflect all agreed-upon details in the legal agreements before making any investment decisions.