Nom du produit
Fabricant Tous les fabricants ADS-TEC Energy Aggreko Alfen BYD Capture Energy Chint Power Systems CRRC Corporation Cubenergy Cummins Delta Electronics e-STORAGE Eaton Envision Energy FENECON Fluence HiTHIUM Energy Storage HOENERGY Hoymiles Huawei Hunan Copower HyperStrong INTILION JinkoSolar Leclanche LG Energy Solution Vertech LS Energy Solution MPINarada NHOA Energy Pomega PotisEdge Prevalon RelyEZ Energy Storage REPT BATTERO Risen Storage Roche Energy Saft Samsung SDI Sermatec Shenzhen CLOU Electronics Shenzhen Jiawei Sungrow SVOLT Energy Technology Tesla TESVOLT Trinasolar Wartsila WHES
Capacité énergétique nominale Toutes les capacités < 2 MWh 2 à 5 MWh 5 à 10 MWh > 10 MWh
Durée Toutes les durées 0.5 heure 1 heure 2 heure 4 heure 5 heure 6 heure 8 heure 10 heure
Taux de C Tous les C-Rates 0.1 C 0.5 C 0.5 P 0.6 C 0.13 C 0.13 P 0.25 C 0.25 P 1 C 1 P 2 C
Chimie des accumulateurs Toutes les chimies LFP (Lithium Iron Phosphate, LiFePO4) NCA (Lithium Nickel Cobalt Aluminum) NMC (Lithium Nickel Manganese Cobalt Oxide)
conteneurisé Tous les types Non Oui
Méthode de refroidissement Toutes les méthodes air forcé Air forcé (CVC intégré) Armoires PCS/Batteries : Refroidissement liquide (autonome) ; Armoire de commande : Refroidissement par air (autonome) Batteries refroidies par liquide ; onduleurs refroidis par air forcé et par eau. Batteries refroidies par liquide, CVC (température ambiante à l'intérieur du conteneur) Boîtier de batterie refroidi par liquide, PCS à air forcé Chauffage et refroidissement intégrés au niveau de la cellule Climatisation industrielle Climatiseur industriel Contrôle intelligent de la température : 3 °C Échangeur de chaleur, ventilateur refroidi par air et à température contrôlée Gestion de température à haute efficacité Gestion thermique Gestion thermique intégrée Installation de climatisation (CVC) Liquide - Eau glycolée (batterie), Refroidissement par air forcé (PCS) mélange d'eau et de glycol Modules refroidis par liquide (batterie), refroidissement hybride (onduleur) Ne nécessite aucun entretien de vidange du liquide de refroidissement Onduleur PCS : Refroidissement par air forcé ; Bloc CC : Refroidissement par liquide PCS : Refroidissement par air forcé ; Batterie : Refroidissement liquide PCS = Refroidissement par air, Pack = Refroidissement par liquide (R134a) Refroidissement entièrement liquide (PC + batterie) Refroidissement intelligent à l'eau Refroidissement intelligent par air Refroidissement intelligent par air (PCS) ; Refroidissement liquide (batterie) Refroidissement intelligent par air (PCS) Refroidissement liquide (batterie) Refroidissement intelligent par air (PCS), refroidissement liquide (batterie) Refroidissement liquide Refroidissement liquide - Circuit fermé intégré Refroidissement liquide - Eau / Glycol (batterie), Air pulsé (PCS) Refroidissement liquide (batterie) et air pulsé (PCS) Refroidissement liquide (batterie), Refroidissement intelligent par air (électronique de puissance) Refroidissement liquide (batterie), refroidissement intelligent par air (PCS) Refroidissement liquide (batterie), refroidissement par air (onduleur) Refroidissement liquide (batterie), refroidissement par ventilateur (PCS) Refroidissement liquide (batteries), air forcé (onduleur) Refroidissement liquide (côté CC) / Refroidissement par air (côté CA) Refroidissement liquide (eau glycolée), climatisation ambiante Refroidissement liquide (eau-éthylène glycol) Refroidissement liquide (Éthylène glycol : solution aqueuse 50 % v : 50 % v) Refroidissement liquide (Éthylène glycol : solution aqueuse à 50 % v/v) Refroidissement liquide (intégré) Refroidissement liquide (mélange d'eau et de glycol) Refroidissement liquide (refroidissement centralisé, shunt multi-étages, canal à flux parallèle, régulation par étranglement), régulation intelligente de la température Refroidissement liquide + CVC Refroidissement liquide avec refroidisseur central Refroidissement liquide double face Refroidissement liquide intelligent Refroidissement liquide intelligent (batterie), refroidissement par air forcé (PCS) Refroidissement liquide pour batteries / Refroidissement par air forcé avec contrôle de vitesse pour PCS Refroidissement liquide pour batteries / Refroidissement par air forcé pour PCS Refroidissement liquide, CVC Refroidissement liquide, CVC intelligent Refroidissement liquide, solution aqueuse d'éthylène glycol à 50 % Refroidissement par air Refroidissement par air (climatisation pour batteries) Refroidissement par air (onduleur) Refroidissement par air forcé Refroidissement par air naturel, refroidissement par air pulsé, climatisation (en option) Refroidissement par air ou par liquide Refroidissement par air+ (Options de refroidissement liquide) Refroidissement par immersion liquide Refroidissement par ventilateur (CC), Climatisation industrielle (armoire), Refroidissement par air pulsé (PCS) Refroidissement par ventilateur intelligent Refroidissement par ventilateur, climatisation industrielle Refroidissement par ventilateur, refroidissement par air pulsé, climatisation industrielle Refroidissement passif Refroidissement/chauffage liquide intelligent Système de gestion thermique avancé basé sur une unité de climatisation et des ventilateurs contrôlables Système de refroidissement liquide Système de refroidissement/chauffage liquide intelligent pour batterie Unité de climatisation et ventilateurs réglables
Protection de l'enceinte Toutes les évaluations Battery compartment IP55, PCS compartment IP66, Electrical room IP54 Battery Compartment: IP65, Electrical Compartment: IP54 Battery compartment: IP65, PCS compartment: IP66, Electrical room: IP54 Battery rack: IP56; Inverter: IP65; Connection Cabinet: IP55 Cabinet: IP55 / Type 3R Cabinet: IP55 / Type 3R, Battery modules: IP66, Power modules: IP65 Container IP55, Module IP67 Container-IP55, Pack-IP65, PDU-IP55 High ingress protection design IP 55 IP 64 IP3X IP20 IP54 IP54 (Battery Container, Electrical Compartment), IP65 (PCS) IP54 (Battery) / IP20 (Inverter) IP54 (IP67 for battery pack) IP54/IP55 (Battery Compartment), IP54 (Electrical Compartment), IP54 (PCS) IP55 IP55 – Excl. TMS (Temperature Management System) IP67 – Module IP55 (Battery cabinet) / IP65 (PCS) IP55 (Battery Compartment), IP54 (Electrical Compartment) IP55 (Battery Parts), IP54 (Electrical Parts) IP55 (Battery), IP66 (Inverter) IP55 (Enclosure), IP67 (Battery), IP65 (PCS) IP55 (enclosure), IP67 (high voltage module) IP55 (optional C5) IP55 (Pack IP67, PCS IP66) IP55 (Pack IP67) IP55 (PCS IP65) IP55 (System), IP66 (Inverter) IP55 / NEMA 3R IP55 / Type 3R IP55 system-level (IP65 energy block) IP55-Container, IP67-Module IP55, UL50-3R IP55/Type 3R IP56 IP66 IP66 / NEMA 3R (Main enclosure), IP20 (Thermal system) IP68 NEMA 3 / IP55 NEMA 3R NEMA 3R / IP54 NEMA type 3R (IP54) NEMA Type 3R, IP55 Pack-IP65, PDU-IP65, Container-IP55, PCS-IP66 PCS Inverter: NEMA 4X; DC Block: NEMA 3R / IP54 PCS Inverter: NEMA 4X; MV Transformer: NEMA 3R; DC Block: NEMA 3R / IP54 Splash-proof Vandal-proof one-box design
Certifications Toutes les certifications 2014/30/EU, 2014/35/EU, IEC 62477-1, UL 1741SB, CEI 0-16, IEEE 1547.1-2020, G99, EN 55011/CISPR11, IEC 61000-6-2, IEC 61000-6-5 CE marked, EN 61000-6-2, EN 61000-6-4, EN 62477-1, IEC 62477-1, IEC 62933-2, Fault Ride Through Capability CE-EMC, CE-LVD, TÜV MARK, UN38.3, IEC 61000-6-2, IEC 61000-6-4, IEC 62477-1, IEC 62619, IEC 63056, EU 1542/2023 CE, IEC 62619, IEC 62477, IEC 61000, IEC 63056, UL 9540A CE, IEC 62619, IEC 63056, UL 9540A, EN 50549-1, EN 50549-2, UN 3536 CE, IEC 62619, UL 9540A, EN 50549-1, EN 50549-2, UN 3536 CE, UKCA, IEC62933 series, UN3536, IEC60364, IEC60664-1/4, IEC61140, NEN1010, NEN3140, IEC62477, EMC Directive (61000-6-2/4, IEC62052-11/21/22/23), IEC62933-5-2, IEC62619, UL9540A, PGS37-1, EU Battery Legislation/Directive, UL1973, IEC63056, UN38.3, NIS2 Directive (In Progress), IEC62433 (In Progress), IEC61850 (Optional), EN50549-1 CE, UN 38.3, IEC 62619:2022, IEC 62477-1:2022 CE, UN 38.3, IEC62619, IEC 60730, UL 9540A, EU-BattV 2023 CE, VDE 2510-50, VDE 4105, VDE 4110, UN38.3, IEC62619, EMV CE, VDE 2510-50, VDE 4105:2018-11, VDE 4110:2023, TOR Erzeuger Typ A 1.1, UN38.3, IEC62619, EMV (complete), Sweden (registered Rikta Rätt), Netherlands (Synergrid C10/11 planned) CE(IEC61000, IEC62619, IEC62477), UN3480, UN38.3, MSDS EN 61000-6-2, EN 61000-6-4, EN 62619, IEC 62477, IEC 62281, IEC 62933-5-2, UN 38.3, UL 1973, NFPA 855, UL 9540A, UL 9540, NEMA 3R, REACH 1907/2006 EC, UKCA, CE, IEC 61000-6-4 + AMD1, IEC 62109-1, IEC 62109-2, IEC 61683, UL1741, VDE-AR-N-4110, VDE-AR-N-4120, VDE-AR-N-4130, ENA-EREC G99 EN 61000-6-2, EN 61000-6-4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, NFPA 855, UN 38.3, UL 1973, UL 9540, UL 9540A, UKCA, CE, IEC61000-6-2, IEC62920 + AMD1, IEC62109-1, IEC 62109-2, IEC61683, IEC62477-1, VDE-AR-N-4110, VDE-AR-N-4120, VDE-AR-N-4130, ENA-EREC G99 EN61000, IEC62619, IEC60730, IEC62477, IEC62933, UL9540A, UL1973, UL9540, NFPA855/68/69, UN38.3 EN61000, IEC62619, IEC60730, IEC62477, IEC62933, UL9540A, UL1973, UL9540, NFPA855/68/69, UN38.3, EN50549, G99, VDE4110, VDE4120, UL1741, IEEE1547 EUPD Research Top Innovation 2025, EUPD Research Award Top Brand EMS Deutschland 2024/25, Top Innovator 2025 GB/T 34131-2017, IEC/UL 60730 (BMS); GB/T 36276-2018, IEC 62619, UL 1973, UL 9540A (Battery) GB/T 34131-2023, IEC/UL 60730 (BMS); GB/T 36276-2018, IEC 62619, UL 1973, UL 9540A (Battery); IEC 61000, VDE-AR-N 4110: 2018, VDE-AR-N 4120: 2018, G99, NTS 631 V2.1 (Type B/C/D), GB/T 34120-2017, GB/T 34133-2017, IEC 62477-1, EN 50549 (PCS) GB/T 36276-2018 Lithium Ion Battery for Electrical Energy Storage, GB/T 36548-2018 Test Specification for Electrochemical Energy Storage System Connected to Power Grid, GB/T 478-2010 General Specifications For Static Protection, Security and Automatic Equipment, GB/T 34120-2017 Technical Specification for Power Conversion System of Electrochemical Energy Storage System, GB/T 34133-2017 Testing Code for Power Converter of Electrochemical Energy Storage System GB/T 36276-2018, GB/T 36548-2018, GB/T 478-2010, GB/T 34120-2017, GB/T 34133-2017 GB/T 36276-2018, UL1973, UL9540, UL9540A, UN38.3, IEC62619, NFPA69, NFPA70, NFPA855, NFPA68 IEC 60730, IEC 62619, IEC 62933, IEC 62477, IEC/EN 61000, CE-conformity, UN 38.3 IEC 61000-6-2/4, IEC 62477-1, IEC 62619, IEC 62933-5-2, IEC 63056, CE, UL 1973, UL 9540, UL 9540A, UN38.3 IEC 61000, IEC 62477-1, IEC 62619, IEC 63056, IEC 60529, UL 9540A, UL 1973, UN 3536, UN 38.3 IEC 61619, IEC 62477, UL1973, UL9540, UL9540A, NFPA 855 & NFPA 70E, CE, UL, UL60730-1 (BMS) IEC 62109-1/-2, IEC 61000-6-2/-4, EN 50549-1/EN 50549-10, G99, VDE-AR-N 4105 / VDE V 0124, CEI 0-21, C10/11, NRS 097-2-1, UN 38.3, IEC 62477, IEC 63056 IEC 62477-1, IEC 62619, IEC 63056, IEC 60730, IEC 61000-6-2 & IEC 61000-6-4, IEC 62933 IEC 62477, IEC 62619, UL 1973, UL 9540, UL 9540A IEC 62619, IEC 62477-1, UL 1973:2022, UL9540A, CE, UL, ISO 9001, QS 9000, ISO 14000, IEC 62443-4-2, UN3536 IEC 62619, IEC 62477-1, UL 1973:2022, UL9540A, CE, UL, REACH, ISO 9001, QS 9000, ISO 14000, IEC 62443-4-2, UN3536 IEC 62619, IEC 62477, UL 1973, UL 9540, UL 9540A, CE, UL, REACH, ISO 9001, QS 9000, ISO 14000, IEC 62443-4-2, UN3536 IEC 62619, IEC 63056, IEC 61000, IEC 62477-1, IEC 62933-5-2, UL9540A IEC 62619, IEC 63056, IEC 61000, IEC 62477-1, IEC 62933-5-2, UN3536, UN38.3, UL9540A IEC 62619, IEC 63056, IEC 61000, IEC 62477, UN 38.3, IEC 62040, UL9540A, CEC list IEC 62619, IEC 63056, IEC 62040, IEC 62477, IEC 61000, IEC 62933, UN 38.3 IEC 62619, IEC 63056, IEC 62040, IEC 62477, IEC 61000, UN 38.3, AS/NZS 4777.2, AS/NZS 3000 IEC 62619, IEC 63056, IEC 62477-1, IEC 62933-5-2, IEC 61000-6-2, UL 9540A, NFPA 855, NFPA69, optional NFPA68, UN38.3/UN3536 IEC 62619, IEC 63056, IEC61000, IEC 62477-1, IEC62933-5-2, UN3536, UN 38.3 IEC 62619, IEC 63056, IEC61000, IEC 62477-1, IEC62933-5-2, UN3536, UN 38.3, UL9540A IEC 62619, UL 9540, UL 9540A, UL 1973, UN 38.3, UN 3536, CE Marking IEC 62933, UL9540A, EMC, IEC 62619, EN 50549, G99, VDE4105, CEI016, CEI021, AS4777.2, C10/11, UN38.3 IEC/EN 60730-1, UL60730-1, GB/T 34131-2017, GB/T 36276-2018, IEC 62619-2017, ANSI/CAN/UL 1973: 2022, ANSI/CAN/UL 9540A: 2019, UN 38.3, EN 62477-1, EN IEC 61000-6-1:2019, EN IEC 61000-6-2: 2019, EN IEC 61000-6-3: 2021, EN IEC 61000-6-4: 2019, CE, GB/T 34120, GB/T 34133, EN 50549-1, EN 50549-2, CEI 0-21, CEI 0-16, NRS 097-2-1: 2017, EN 50549+Deviations of Netherlands/C10/11/Greece/Sweden, NC RFG, PTPIREE, G99, VDE-AR-N 4105: 2018, DIN VDE V 0124-100: 2020-06, UNE 217001: 2020, UNE 217002: 2020, NTS V2.1 IEC/EN62619, IEC/EN63056, IEC/EN61000, FCC, IEC/UL60730, UL1973, UL9540A, IEC/EN62477, UL9540, UN38.3, UN3536 IEC/EN62619, IEC/UL60730, IEC/EN62477, IEC/EN61000, IEC/EN300328, UN38.3, UN3480 IEC/EN62619, IEC/UL60730, IEC/EN62477, IEC/EN61000, UN38.3, UN3480, GB36276, GB/T34131 IEC/EN62619, IEC/UL60730, IEC/EN62477, IEC/EN61000, UN3536, UN38.3, UN3480, IEC63056 IEC61000-6-2/4, IEC62619, IEC62477-1, IEC62933-5-2, UL1973, UL9540, UL9540A, NFPA68&69 (Optional) IEC61000, IEC62477, IEC62619, EN50549-1/10, NRS 097-2-1, UN38.3 IEC61000, IEC62477, IEC62619, EN62109-1/2, EN50549-1/10, VDE 4105, NTS 631 Type A, C10-11, NRS 097-2-1, PEA&MEA, VFA 2019, VDE 0126, G99-1/9 Type A, UN38.3 IEC61000, IEC62619, IEC62477, IEC63056 IEC61000, IEC62619, IEC62933, AS3000, UKCA, G99, UN38.3/UN3536, CE, IEC62477 IEC62109-1, IEC 61000-6-2, IEC 61000-6-4, UN38.3 IEC62271-100, IEC62271-103, IEC62271-200, IEC60076, IEC62477-1, EN50549-2, IEC61000-6-2/4, ANSI C57.12.10/20 IEC62619, IEC60536, UL1973, UL9540A, UN38.3, EU Battery Regulation 2023/1542, AS/NZS 3000, IEC61558, IEC624777-1:2022, IEEE 1547, AS/NZS 4777, CE/UKCA, LVD 2014/35/EU (IEC 62477-1:2022), EMC Directive 2014/30/EU (IEC61000-6-2 & -6-4), REACH, IEC62933 (-5-1,-5-2), CSC for container IEC62619, IEC61000, IEC62477, UN38.3, UL9540A IEC62619, IEC62477, IEC61000, UN38.3, UN3536, UL9540A IEC62619, IEC62629, UN62620, IEC60730, IEC63056, IEC61000, UN38.3 IEC62619, IEC63056, IEC60529, IEC62477, UL9540A, UL1973, UL9540, UL50E, NFPA855, NFPA69, UN38.5, UN3536 IEC62619, IEC63056, IEC60730, IEC62477, IEC61000, UL1973, UL9540A, UL9540, FCC, UN38.3, UN3536, NFPA68, NFPA69, HMA, NFPA855 IEC62619, IEC63056, IEC61000-6-2/-4, IEC62477-1, EU1542 (Design satisfaction), UL9540A, UN38.3 IEC62619, IEC63056, IEC61000-6-2/-4, IEC62477-1, UN38.3 IEC62619, IEC63056, IEC61000, IEC62477, UL9540A IEC62619, IEC63056, IEC62477-1, IEC61000-6-2/-4, IEC60730, UN38.3, EU1542 (design meets), wireless RED, UL9540A, RoHS, REACH; PCS grid connection certification: European standard EN50549-1&-2&-10; Germany VDE4110, VDE4120; Spain NTS631:2019, UNE217002:2020, UNE217001:2020; UK G99; Italy CEI 021/16 IEC62619, IEC63056, IEC62477-1, IEC62933-5-2, IEC61000-6-2, UL9540A, NFPA69, NFPA855 and UN38.3/UN3536 IEC62619, IEC63056, IEC62477, IEC61000, EN50549-10, EN50549-2, VDE4110, UL9540A, UN38.3 IEC62619, IEC63056, IEC62477, IEC61000, UN38.3, EN50549-1, EN50549-2, EN50549-10 IEC62619, UL1642, UL9540A, UL1973, IEC61000, IEC62477-1, IEC63056, UL9540, NFPA69, NFPA855 IEC62619, UL1973, UL9540A, IEC60730-1, UN38.3, IEC63056, IEC62477-1, EN IEC 61000-6-2/4, UN3536 IEC62619, UL1973, UL9540A, IEC63056, IEC61000, UN38.3 IEC62619, UL9540A, UL1973, IEC61000 IEC62619, UN38.3, UL1973, UL9540A IEEE693 NFPA 855, NFPA 68 RoHS, IEC62477-1, IEC62040-1, IEC61000-6-2, EN55011, UL9540A, IEC62619, UN3536, etc. RoHS, IEC62477-1, IEC62040-1, IEC61000-6-2, IEC62933-5-2, UL9540A, IEC62619, UN38.3 RoHS; GB/T 36276-2018; GB/T 33582; UL9540A; UN38.3; ISO 9227:2017; IEC 60529; IEC/EN 62477-1; IEC/EN 62040-1; IEC/EN 61000-6-2; IEC/EN 61000-6-4; EN 55011 UL 1642, UL 1973, UL 9540, UL 9540A, UL 1741 SA, IEEE 1547 UL 1973, UL 9540, UL 9540A, FCC part 15B, NFPA69, UN3536, UN 38.3 UL 1973, UL 9540, UL 9540A, FCC part 15B, NFPA855, UN3536, UN 38.3 UL 1973, UL 9540A, IEC 62619, IEC 62477-1, EN 61000 6-2/6-4, CE, ISO9001, ISO14001, ISO27001, ISO45001, EU Battery Directive, EU RoHS Directive, EU WEEE Directive, IEC 61000-6-2, IEC 61000-6-4, IEC 60364-1:2005, IEC 61439-2:2011, IEC 62271-200, IEC 60076, IEC 62109-1, IEC 62109-2, UN 38.3, UN 3536, UN 3481 UL 9540 (System), UL 1741 SA, SB (Power conversion system), UL 1973, UL 9540A (Battery), ISO9001 UL 9540A UL 9540A, IEC 62619, IEC 61000-6-2, EN55011, IEC 62933-5-2, UN 38.3 / UN 3536, IEC 62477-1, IEC 62443-4-2 UL 9540A, IEC 62619, IEC 63056, IEC 62933-5-2, IEC 61000-6-2, IEC 61000-6-4, IEC 62477-1 UL 9540A, NFPA 855 (2023 & 2026 editions), IEC 62443-4 UL 9540A, NFPA 855 (2023 & 2026 editions), Large-Scale Fire Test, Active Ignition Mitigation System (AIMS) Testing, IEC 62443-4, Noise Compliance Testing UL 9540A, UL 1642, UL 1973, IEC 62933, IEC 62619, IEC 63056, IEC 62477, IEC 61000 - 6 - 2, IEC 61000 - 6 - 4, UN 38.3, UKCA, CE, NFPA 855, AS3000 UL 9540A, UL 1642, UL 1973, NFPA 69, NFPA 68, NFPA 855, IEC 62933, IEC 62619, IEC 63056, IEC 62477, IEC 61000-6-2, IEC 61000-6-4, UN 38.3, UN 3536, ISO 27001, IEC 62443-2-4, IEC 62443-4-1, IEC 62443-4-2 UL 9540A, UL 9540, UL 1973, NFPA 68, NFPA 69, IEC 62619, IEC 63056, IEC 62477, IEC 60730, IEC 62933, EN 50549 UL/IEC, NFPA68 and 69, UL9540A, UL9540, IEC62933, IEC 62477-1, UL-1741, CSA C22.2 No. 107.1, FCC Part 15, IEC 61000-6-2, IEC 61000-6-4 UL/IEC, UL1741, UL1741SA/IEEE1547, NFPA68/69/72/855, UL 9540A Cell, Module, Unit UL1741, IEEE1547, UL1741SB, UL1973, UL9540A, UL9540, NFPA68, NFPA69 UL1741, UL1741-SA, UL1741-SB, FCC, CSIP, IEC62619, UL1642, UL9540A, IEC61000, IEC62477-1, IEC63056, UL1973, UL9540 UL1741, UL1741-SA, UL1741-SB, FCC, CSIP, UL9540, IEC62619, UL1642, UL9540A, IEC61000, IEC62477-1, IEC63056 UL1973, UL9540, NFPA855 UL1973, UL9540A ed4, UL9540, UL1741, IEEE1547, UN38.3, NFPA855, NFPA70 UL9540 certified, NFPA 855, NFPA 69, NFPA 68 optional UL9540, IEC 62933 UL9540, IEC62619, IEC62109, UN3536 UL9540, UL1973, UL1624, UL1741 (SA, SB), IEEE1547, UN 38.3, NFPA 855, NFPA 69, NFPA 72, IFC/CFC UL9540, UL1973, UL1624, UL1741, IEEE 1547.1, NFPA 855 UL9540, UL1973, UL1642, UL1741 (SA, SB), IEEE1547, UN 38.3, NFPA 855, NFPA 69, NFPA 72, IFC/CFC UL9540, UL9540A, CE, IEC, KC, KBIA UL9540, UL9540A, CE, IEC, UN3536 UL9540, UL9540A, UL1973, UN38.3 UL9540A unit-level compliance, compliant with North American and international standards UL9540A, NFPA69, IEEE693 UL9540A, UL1973, IEC62619, IEC62477, UL9540, IEC62933, NFPA855, EN50549, IEEE1547, G99, UL1741, UN38.3, UN3536 UL9540A, UL1973, IEC62619, IEC62477, UL9540, IEC62933, NFPA855, EN50549, IEEE1547, G99, UL1741, UN38.3, UN3536, DNV Bankability UL9540A, UL1973, IEC62619, IEC62477, UL9540, IEC62933, NFPA855, EN50549, IEEE1547, G99, UL1741, UN38.3, UN3536, IEC 62933 UL9540A, UL1973, UL9540, UL50E, NFPA855, NFPA68 (optional), NFPA69, HMA, UN 38.3 / UN 3536, IEC62619, IEC63056, IEC60529, IEC62477 UL9540A, VDE 4110, UL9540A certified (battery packs) UN 38.3, IEC 62619, UL 1973, UL 9540A (battery cell/module); IEC 63056:2020, IEC 62619:2022, VDE-AR-E 2510-50:2017, IEC 61010-1:2020, EN 61508: 2010 Part 1-7-SIL 2 (system) UN38.2, IEC62619, IEC62629, UL9540A, UL1973, UL9540, NFPA855 UN38.3, CE, IEC62619, VDE, EN50549-1, C10/26, NTS Type A/Type B, CEI 0-21, G99-1/9 Type A, Cyper security, PEA, MEA UN38.3, IEC, GB UN38.3, IEC61000, IEC62933-5-2, IEC62619, IEC60730, IEC63056, IEC62477, UL9540A, UL9540, UL1973, NFPA855, NFPA68, NFPA69, UN3536 ΕΝ 61000-6-2, EN 61000-6-4, EN 62619, UN 38.3, 2006/66/EG (BAT Directive), ΕΝ 62109-1, EN 62040-2, EN 61439-1, EN 61439-2, VDE-AR-N 4105, VDE-AR-N 4110, EN 50549-1, TOR Generator Type A, TOR Generator Type B, 2014/53/EU (RED), 2014/30/EU (EMC), 2014/35/EU (LVD)
Onduleur/PCS groupé Toutes les options Non Not provided Oui
Réinitialiser les filtres